Skip to content

Surecut Plasma Cutting

Filter by Product Range

A unique system of Arc initiation removes the traditional requirements of potentially dangerous levels of high frequency.

SC40

Cooling Method
Air-Cooled
Rating
40A
Cutting Thickness
8-12mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
100 l/min 210 scfh
Pilot
Electrode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC40 Product Image

SC60

Cooling Method
Air-Cooled
Rating
60A
Cutting Thickness
12-20mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
110 l/min 230 scfh
Pilot
Electrode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC60 Product Image

SC80

Cooling Method
Air-Cooled
Rating
80A
Cutting Thickness
20-25mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
110 l/min 230 scfh
Pilot
Electode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC80 Product Image

SC80R

Cooling Method
Air-Cooled
Rating
80A
Cutting Thickness
20-25mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
110 l/min 230 scfh
Pilot
Electrode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC80R Product Image

SC120

Cooling Method
Air-Cooled
Rating
120A
Cutting Thickness
30-35mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
200 l/min 420 scfh
Pilot
Electrode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC120 Product Image

SC120R

Cooling Method
Air-Cooled
Rating
120A
Cutting Thickness
30-35mm
Duty Cycle
60%
Gas
Air/N2
Gas Pressure (Bar)
4.5-5.0
Gas Pressure (PSI)
65-75
Gas Flow
200 l/min 420 scfh
Pilot
Electrode to Tip
Ignition
Back Striking w/o HF
Post Flow
90 sec
SC120R Product Image